SEFAR® Architecture TENARA® Fabric is inherently non-flammable, and does not support a flame. It has been tested in accordance with a number of industry protocols as shown below. If you would like to know if SEFAR® Architecture TENARA® Fabric has been tested in accordance with a particular test not listed below, or require a copy of the test report, please contact us with details.

Test Standard Results
NFPA 701: Method 1: Flame Propagation of Textiles and Films
3T20HF, 3T40HF, 4T20HF, 4T40HF tested
Part 1, small scale - PASS
NFPA 701: Large Scale, Test Method #2, 4T20HF PASS
FTM 191A: Method 5902
ASTM D64-13 Flame Resistance of Cloth:
Vertical Flame Test, Type 2 tested
After-flame time: < 1.5 seconds
After Glow Time: 0 seconds
Char Length: 1 inch
ASTM E84
UL 723
ANSI/NFPA 255
UBC 801: Surface Burning Characteristics of Building Materials 3T40, 4T40 tested
Flame Spread: -5 or less
Smoke Index: -70 or less
Meets "Class A" Flame Spread Rating
Note: Typical Flame Spread Classification, aka Flame Spread Rating or "Index" definitions are as follows:
Class 1 (or A) 0-25 Flame Spread
Class 2 (or B) 26-75 Flame Spread
Class 3 (or C) 76-200 Flame Spread
* Consult local building requirements
DIN EN 13501-1
Includes Single Burning Item (CBI) test according to DI EN 13823 and ignitability test according to DIN EN SIO 11925-2.
Type 1 and Type 2 tested
Class: Bs1, d0
Fire behavior: B
Smoke Production: s1
(Smoke Growth Rate Index SMOGRA ≤ 30ms²/s², Total Smoke Production TSP 600 ≤ 500m²)
Flaming droplets/particles: dO (No)
UL 94 All components: UL94 V-0